Recent Posts

info@electricalgoodssuppliers.com

LC1F630M7

Sale!

LC1F630M7

In Stock
SKU: LC1F630M7 Category:

Product Description

Main

Range TeSys
Product name TeSys F
Product or component type Contactor
Device short name LC1F
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-3
AC-4
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 1000 A (<= 40 °C) at <= 440 V AC AC-1
630 A (<= 55 °C) at <= 440 V AC AC-3
Motor power kW 335 kW at 380…400 V AC 50/60 Hz AC-3
375 kW at 415 V AC 50/60 Hz AC-3
400 kW at 440 V AC 50/60 Hz AC-3
400 kW at 500 V AC 50/60 Hz AC-3
450 kW at 1000 V AC 50/60 Hz AC-3
200 kW at 220…230 V AC 50/60 Hz AC-3
100 kW at 400 V AC 50/60 Hz AC-4
450 kW at 660…690 V AC 50/60 Hz AC-3
[Uc] control circuit voltage 220 V AC 40…400 Hz

Complementary

[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 1000 A at <= 40 °C
1250 A
Rated breaking capacity 5040 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 5050 A <= 40 °C 10 s
4400 A <= 40 °C 30 s
3400 A <= 40 °C 1 min
2200 A <= 40 °C 3 min
1600 A <= 40 °C 10 min
Associated fuse rating 630 A aM at <= 440 V
1000 A gG at <= 440 V
Average impedance 0.12 mOhm at 50 Hz – Ith 1000 A
[Ui] rated insulation voltage 0.12 mOhm at 50 Hz – Ith 1000 A1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole 120 W AC-1
48 W AC-3
Mounting support Plate
Standards EN 60947-1
EN 60947-4-1
IEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
Product certifications ABS
BV
CSA
DNV
LROS (Lloyds register of shipping)
RINA
RMRoS
UL
CB
Connections – terminals Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable
end
Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable
end
Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable
end
Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Power circuit : bolted connection
Power circuit : bar 2 x (60 x 5 mm)
Tightening torque Control circuit : 1.2 N.m
Power circuit : 58 N.m
Control circuit voltage limits 0.85…1.1 Uc at 55 °C operational 40…400 Hz
0.25…0.5 Uc at 55 °C drop-out 40…400 Hz
Inrush power in VA 1650 VA at 20 °C (cos ϕ 0.9) 40…400 Hz
Hold-in power consumption in VA 1650 VA at 20 °C (cos ϕ 0.9) 40…400 Hz22 VA at 20 °C (cos ϕ 0.9) 40…400 Hz
Heat dissipation 20 W
Operating time 100…200 ms opening
40…80 ms closing
Mechanical durability 5 Mcycles
Operating rate 1200 cyc/h at <= 55 °C

Environment

IP degree of protection IP20 front face with shrouds (ordered separately) conforming to IEC 60529
IP20 front face with shrouds (ordered separately) conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C
Operating altitude 3000 m without derating
Mechanical robustness Vibrations resistance contactor open 2 Gn, 5…300 Hz
Shocks resistance contactor open 9 Gn for 11 ms
Shocks resistance contactor closed 15 Gn for 11 ms
Vibrations resistance contactor closed 4 Gn, 5…300 Hz
Height 255 mm
Width 309 mm
Depth 304 mm
Product weight 18.6 kg
Name
Email
Mobile No.